Loading...
- The motor's charging section including lead wire is made airtight by the herminal box to provide the protection from the dust and moisture.
- Therefore, the motor can be used in the harsh environment.
- The classification of the device protection structure for our T type terminal box motor is IP54.
- The motor features a compact design.
- The ground terminal is attached to the motor. However, Type (6~15W)of the single-phase induction motor does not have a built-in ground inside the terminal box.
- Since the motor is so structured as to make the piping work easier, it is excellent in connection work. The cable is firmly fixed to provide the stronger tension when wiring the cable.
- The terminal box cover is made of PC resin which is excellent in insulation and stiffness.
- The T type terminal box uses a product that provides high reliability.
- Please use AWG NO.24~AWG NO. 10 (0.25 mm²~4.0mm²) for the lead wire. At this time, the length of the peeled-off lead wire should be about 8mm.
Item | Specification |
---|---|
Insulation Resistance | 100MΩ or more when 500V megger is applied between the windings and the housing after rated motor operation under normal ambient temperature and humidity. |
Dielectric Strength | Sufficient to withstand 1500V at 50/60Hz applied between the windings and the case after rated motor operation under normal ambient temperature and humidity |
Temperature Rise | Class A (below 65deg), class E (below 75deg), class B (below 85deg) (measured by thermometer after rated operation) |
Insulation Class | Class E(120℃),Class B(130℃), UL approval motor class A (105℃) |
Overheat Protection Device | Built-in thermal protector (automatic return type) : Open 130℃±5℃ Close 82℃±15℃ |
Ambient Temperature | -10 ℃ ~ + 50 ℃ (UL, CE certified motor is -10 ℃ ~ 40 ℃) |
Ambient Humidity | 85% maximum (non condensing) |
1. TERMINAL BLOCK BOX TYPE (T TYPE)